Backside Rinse Dispense

Backside rinse supplies liquid from a pressure can or a customer-supplied pressurized House Source to an upward-facing nozzle beneath the spinning substrate. It removes unwanted process material from the back side of the wafer, with rinse timing integrated into the DataStream recipe.

  • Pressure-can sizes from 1 to 10 gallons
  • Standard stainless-steel or PFA-coated vessels
  • ⅛″ dispense line and valve
  • Adjustable flow; no suckback control is needed

House Source: Liquid must be pressurized at the equipment and customer-regulated to 29 psi or less.

Requires a dispense control box, sold separately. One box supports up to four dispenses. Need more than four dispenses? Add dispense control boxes to expand your system.

⅛″ dispense line and valve · Backside rinse nozzle · no suckback

Select your configuration.

Product Information

Overview

Backside rinse directs a compatible liquid upward onto the underside of a spinning substrate. It washes away photoresist, developer solution, or other process material carried onto the back side, helping reduce residue transferred to later handling and process surfaces.

The rinse is supplied from a pressure can or a customer-supplied pressurized House Source through a dedicated ⅛″ valve and line. Reservoir size and vessel finish are selected around liquid usage, refill frequency, and chemical compatibility.


Key Capabilities

Nozzle position, flow, recipe timing, and spin conditions work together to rinse the intended area. DataStream coordinates the rinse step with the equipment process.

The backside-rinse valve has no suckback control. With the nozzle directed upward, gravity handles drainage after the dispense stops. For the pressure can option, an installed float sensor monitors the supply through DataStream; the dispense control box is required and sold separately.

House Source uses the pressure supplied by the customer’s liquid line. It does not draw from an unpressurized container. Regulate the liquid supply to 29 psi or less at the equipment; no local pressure can or reservoir float sensor is included with this option.

Choose the Material Source

Select a pressure can for a local reservoir, or House Source for a compatible customer-supplied pressurized liquid line. The House Source SKU is HS-1-BSR; it uses the same fixed ⅛″ line and valve size.

House Source requirement: The liquid must arrive pressurized at the equipment and be regulated by the customer to 29 psi or less. Confirm fluid compatibility and available flow.

For the pressure can option:

Select a 1, 2, 3, 5, or 10 gallon reservoir and either a standard stainless-steel or PFA-coated vessel. Confirm the compatibility of the complete wetted path with your rinse liquid.

X-Pro pressure can storage: 1- and 2-gallon pressure cans fit inside the X-Pro in the designated storage area. Pressure cans larger than 2 gallons must be located outside the X-Pro.

The selector combines vessel type and capacity with the fixed ⅛″ line code and BSR outlet. Standard vessels use the PCBE prefix; PFA-coated vessels use PCBTE. For example, a standard 1-gallon system is PCBE-1-1-BSR. Every option on this page uses a ⅛″ line and valve.


Equipment Fit and Process Setup

Specify your Cee® spin coater or developer model, substrate size, process chemistry, and backside cleanliness requirements. Confirm the substrate-holding arrangement and bowl-nozzle position so rinse liquid reaches the intended area. The rinse line connects at the equipment’s rear utility bracket, then feeds the nozzle through the bowl connection. Adjust flow and timing for the material; backside rinse does not use suckback.

A dispense control box is required and sold separately. One box supports up to four dispenses; additional boxes expand the system beyond four.

  • Pressure can option only: Pressure canister with lid, dip tube, closure seal, and an installed empty-reservoir float sensor, in the selected capacity and vessel finish
  • 6 ft of ⅛″ PTFE dispense tubing
  • 6 ft of green ⅛″ urethane tubing with sleeve valve
  • ⅛″ dispense valve without suckback and connection tubing
  • Backside-rinse nozzle and bowl connection for the configured Cee® equipment
  • Backside-rinse inlet connection at the equipment’s rear utility bracket

For the pressure can option, the float sensor is assembled onto the pressure can for supply monitoring through DataStream.

Backside rinse uses an upward-facing nozzle and no suckback control; gravity handles drainage after dispensing.

Purchased separately: The dispense control box.

House Source option: Includes the configured ⅛″ valve, dispense tubing, pneumatic trigger tubing, and backside-rinse nozzle and equipment connections. The customer supplies the compatible pressurized liquid source, pressure regulation to 29 psi or less, and facility-side connection. No pressure can or float sensor is supplied.

Reservoir Capacity

1–10 gal / 3.7–37 L

Vessel Finish

Standard stainless steel or PFA-coated

Wetted Materials

PFA, PTFE, 304/316 stainless steel

Line & Valve Size

⅛″

Nozzle

Upward-facing bowl nozzle; position adjustable

Suckback

No suckback control; gravity handles drainage

Dimensions

Dimensions below apply to the pressure can option only. House Source has no local reservoir. The nozzle installation is matched to the Cee® equipment.

Reservoir Size

1 gallon

Height

11.5″ (29.2 cm)

Diameter

10″ (25.4 cm)

Reservoir Size

2 gallons

Height

14.5″ (36.8 cm)

Diameter

10″ (25.4 cm)

Reservoir Size

3 gallons

Height

18″ (45.7 cm)

Diameter

10″ (25.4 cm)

Reservoir Size

5 gallons

Height

25″ (63.5 cm)

Diameter

10″ (25.4 cm)

Reservoir Size

10 gallons

Height

28″ (71.1 cm)

Diameter

13″ (33.0 cm)

Allow at least 12″ (30.5 cm) above the reservoir for access to the lid and top components.

Utilities

Gas Supply

Nitrogen or clean dry air

Supply Pressure

Pneumatic supply: 70 psi to the dispense control box.

House Source liquid supply: Customer-regulated to 29 psi or less at the equipment.

Reservoir Monitoring

Pressure can option: DataStream empty-reservoir float sensor. House Source: customer-managed supply.

You May Also Like

Need a custom dispense solution?

Need heated dispensing, a special delivery method, or a configuration you don’t see here? Cee® offers custom solutions built around your material, equipment, and process.

See examples of our custom equipment, then contact Cee® to discuss your dispense requirements.