Edge Bead Removal Dispense

Edge bead removal supplies a controlled solvent stream from a pressure can or a customer-supplied pressurized House Source to the wafer perimeter. The manually positioned nozzle removes unwanted coating at the edge, with rinse timing integrated into the DataStream recipe.

  • Pressure-can sizes from 1 to 10 gallons
  • Standard stainless-steel or PFA-coated vessels
  • ⅛″ dispense line and valve
  • Adjustable nozzle position, flow, and suckback

House Source: Liquid must be pressurized at the equipment and customer-regulated to 29 psi or less.

Requires a dispense control box, sold separately. One box supports up to four dispenses. Need more than four dispenses? Add dispense control boxes to expand your system.

⅛″ dispense line and valve · Edge bead removal nozzle

Select your configuration.

Product Information

Overview

Edge bead removal uses a narrow solvent stream to dissolve coating at the outer wafer edge while the substrate spins. Position the nozzle around the desired exclusion area to keep the rinse focused on the perimeter and preserve the central coating region.

A separate pressure can or a customer-supplied pressurized House Source supplies the ⅛″ dispense valve. Choose reservoir capacity around solvent consumption and refill frequency, with standard stainless-steel and PFA-coated vessels available to suit the chemistry.


Key Capabilities

The nozzle can be positioned manually for substrate size and edge exclusion. DataStream coordinates the dispense within the coating recipe, while flow and suckback adjustments help tune delivery and limit trailing drips.

Each pressure can configuration includes a float sensor for empty-reservoir monitoring through DataStream. The dispense control box provides the pressure and valve control for automated delivery and is sold separately.

House Source uses the pressure supplied by the customer’s liquid line. It does not draw from an unpressurized container. Regulate the liquid supply to 29 psi or less at the equipment; no local pressure can or reservoir float sensor is included with this option.

Choose the Material Source

Select a pressure can for a local reservoir, or House Source for a compatible customer-supplied pressurized liquid line. The House Source SKU is HS-1-EBR; it uses the same fixed ⅛″ line and valve size.

House Source requirement: The liquid must arrive pressurized at the equipment and be regulated by the customer to 29 psi or less. Confirm fluid compatibility and available flow.

For the pressure can option:

Select a 1, 2, 3, 5, or 10 gallon reservoir and either a standard stainless-steel or PFA-coated vessel. Confirm the compatibility of the complete wetted path with your EBR solvent.

X-Pro pressure can storage: 1- and 2-gallon pressure cans fit inside the X-Pro in the designated storage area. Pressure cans larger than 2 gallons must be located outside the X-Pro.

The selector combines vessel type and capacity with the fixed ⅛″ line code and EBR outlet. Standard vessels use the PCBE prefix; PFA-coated vessels use PCBTE. For example, a standard 1-gallon system is PCBE-1-1-EBR. Every option on this page uses a ⅛″ line and valve.


Equipment Fit and Process Setup

Specify your Cee® spin coater or developer model, substrate size, process chemistry, and desired edge exclusion. The EBR nozzle is positioned manually at the wafer perimeter. Match solvent flow, suckback, rinse timing, and spin conditions to the coating and exclusion requirements.

A dispense control box is required and sold separately. One box supports up to four dispenses; additional boxes expand the system beyond four.

High-precision EBR with AccuScan™ : Choose a regular AccuScan™ Stream Dispense configuration for the EBR function. The EBR-suffix options on this page are for the manually positioned EBR nozzle.

  • Pressure can option only: Pressure canister with lid, dip tube, closure seal, and an installed empty-reservoir float sensor, in the selected capacity and vessel finish
  • 6 ft of ⅛″ PTFE dispense tubing
  • 6 ft of green ⅛″ urethane tubing with sleeve valve
  • ⅛″ dispense valve with adjustable suckback and connection tubing
  • EBR nozzle and lid connection for the configured Cee® equipment

For the pressure can option, the float sensor is assembled onto the pressure can for supply monitoring through DataStream.

Purchased separately: The dispense control box.

House Source option: Includes the configured ⅛″ valve, dispense tubing, pneumatic trigger tubing, and EBR nozzle and lid connection. The customer supplies the compatible pressurized liquid source, pressure regulation to 29 psi or less, and facility-side connection. No pressure can or float sensor is supplied.

Reservoir Capacity

1–10 gal / 3.7–37 L

Vessel Finish

Standard stainless steel or PFA-coated

Wetted Materials

PFA, PTFE, 304/316 stainless steel

Line & Valve Size

⅛″

Nozzle

Manually positioned at the wafer perimeter

Suckback

Adjustable suckback control

Dimensions

Dimensions below apply to the pressure can option only. House Source has no local reservoir. The nozzle installation is matched to the Cee® equipment.

Reservoir Size

1 gallon

Height

11.5″ (29.2 cm)

Diameter

10″ (25.4 cm)

Reservoir Size

2 gallons

Height

14.5″ (36.8 cm)

Diameter

10″ (25.4 cm)

Reservoir Size

3 gallons

Height

18″ (45.7 cm)

Diameter

10″ (25.4 cm)

Reservoir Size

5 gallons

Height

25″ (63.5 cm)

Diameter

10″ (25.4 cm)

Reservoir Size

10 gallons

Height

28″ (71.1 cm)

Diameter

13″ (33.0 cm)

Allow at least 12″ (30.5 cm) above the reservoir for access to the lid and top components.

Utilities

Gas Supply

Nitrogen or clean dry air

Supply Pressure

Pneumatic supply: 70 psi to the dispense control box.

House Source liquid supply: Customer-regulated to 29 psi or less at the equipment.

Reservoir Monitoring

Pressure can option: DataStream empty-reservoir float sensor. House Source: customer-managed supply.